RC2800PP-PROP PITCH CONTROLLER

Features

  • 10 programmable heading presets
  • RS232 computer interface
  • Compatible with many logging programs
  • Easy to read, accurate digital display
  • Programmable speed control
  • Programmable North or South stop
  • Programmable ramped start and stop
  • Programmable travel limits
  • Speed-ramped start (in manual control)
  • Reverse delay
  • .3 degree target accuracy
A perfect matchup for the OR-2800 Rotator, the RC 2800P can also be programmed for other gear ratios and can accurately control prop-pitch and many other types of azimuth and elevation gearmotors. This controller is supplied with counter kit for motor shaft.

SPECIFICATIONS
Model Number RC2800 (AZ)
Power Requirements 115 / 230 VAC @ 3/ 1.5A, Switchable
Size 8.5 "W x 5" H x8.5" D
Weight 13 lbs.
Color Light Gray
Digit Size 5" for Heading, . 375" for Mode / Speed
Control Switches Tactile 1/2" Diameter, Flush
Input Filters Yes
Microprocessor Type Phillips P80CLS8HFH
Digital Display Indicates Mode, Speed Azimuth / Programming Data
Controls Power Switch, On / Off
Speed Buttons, Increments 1-9
Clockwise & Counterclockwise Buttons, Up & Down
Mode Button
Modes 3 Operational / Run Modes & 17 Program Modes
Standard Outputs Volts 33 VDC @ 12A, Others Optional
Gear Ratios up to 32,000:1
GENERAL OPERATION INFORMATION

"MODE" BUTTONS" The Mode are used to cycle through and select among 3 operationa or "RUN" modes, and 17 "PROGRAM" modes.

RUN MODE 0: The manual operation mode. When the CW or CCw button is depressed, the positioner ramps up from minimum programmed speed to the maximum (9) and stops, without rampdown, when the button is released.

RUN MODE 1: The manual preset mode. The CW and CCW buttons are used to cycle the display up or down from the current heading. After the button is released, the positioner ramps up from the minimum programmed speed and rampsdown to stop at the selected heading.

RUN MODE 2: The programmable preset mode. The CW and CCW buttons are used to cycle the displaythrough 10 preset, preprogrammed headings. After a short pause, the positioner ramps up from the minimum programmed speed and ramps down to stop at the selected heading.

PROGRAM MODES: Modes 3 through 9 are used to calibrate and configure operations. Modes 20 through 29 are reserved for 10 preset headings.

4420 N. Del Mar Ave, Fresno CA 93711 Ph 559.432.8873 FAX 559.432.3059
http://www.m2inc.com    email:sales@m2inc.com